5-Part Hematology Analyzer Calibrator yɛ ade a ɛyɛ den, a ɛwɔ parameter ahorow pii a wɔde gyina hɔ ma a wɔde abɔde a nkwa wom nkwammoaa mu nneɛma a wɔakora so ayɛ de ahyia na wɔahwɛ sɛ automated differential cell counters susuw pɛpɛɛpɛ. Ɛma botaeɛ boɔ a wɔde di dwuma a wotumi de ho to so wɔ mogya dodoɔ a edi mũ ne mogya mu nkwammoaa fitaa nsonsonoeɛ nsusuiɛ mu, na ɛhwɛ hu sɛ wɔbɛtumi ahwehwɛ mu tẽẽ akɔ amanaman ntam gyinapɛn nhwɛsoɔ akwan so.
Dɛn Ne Mogya Ho Nneɛma a Wɔde Di Dwuma / Calibrators?
Wɔ ayaresabea aduruyɛdan mu nhwehwɛmu mu no, calibrators ne controls yɛ reference dwumadi ahorow soronko:
Calibrators a wɔde yɛ nneɛmakyerɛkyerɛ akontaabu mu abusuabɔ a ɛda adwinnade sensor nsɛnkyerɛnne ne honam fam nkwammoaa dodow ankasa ntam, de susuw mfiase titiriw no si hɔ.
Nneɛma a Wɔde Di Dwumahwɛ da biara da nhyehyɛe nhwehwɛmu pɛpɛɛpɛ ne nhyehyɛe no pintinnyɛ wɔ bere tenten mu, hwɛ sɛ ebia susudua no da so ara wɔ gyinapɛn deviation anohyeto a wɔahyɛ mu a wonsakra nhyehyɛe no mfaso nhyehyɛe.
Dwuma a Di wɔ Hematology Quality Control mu
Calibration a ɛyɛ pɛpɛɛpɛ ma wonya mfiase a ɛho hia ma mogya mu nkwammoaa dodow a wɔkan no mpɛn pii:
Nhyehyɛe no Recalibration:Re-de nhwehwɛmu mu pɛpɛɛpɛyɛ si hɔ wɔ nsuo a wɔsiesie titire, optical realignments, anaa component replacements akyi.
Reagent Lot Nsakraeɛ:Teɛ nsakraeɛ a ɛbɛtumi aba wɔ mfitiaseɛ no mu berɛ a ɔresakra nneɛma a wɔde yɛ diluent, lyse, anaa cleaning solutions pii a wɔyɛ no.
Mfiridwuma mu Nneɛma a Wɔde Di Dwuma:Ɛde da biara da aduruyɛdan mu susuw a wɔyɛ no daa no bata akwan titiriw a wɔfa so susuw nneɛma ho a wɔahyɛ da ayɛ ho tẽẽ wɔ ISO 17511 akwankyerɛ ase.
Nteɛso a Wɔde Yɛ Nsakrae:Siesie nhyehyɛe calibration drift a wɔahu wɔ da biara da akontaabu quality control monitoring.
Control Levels / Dwumadie a Wɔde Di Dwuma
Bere a calibrators de mfinimfini nhwehwɛmu pɛpɛɛpɛyɛ sisi hɔ no, companion quality controls di adwumayɛ ho adanse wɔ adwumayɛ mu nsonsonoe ahorow mu:
Level a Ɛba Fam
Ɔhwɛ detector nkate ne low-end linearity, a ɛho hia ma nhwehwɛmu nhwɛsode a ɛwɔ leukopenia a emu yɛ den, thrombocytopenia, anaa mogya a ɛtɔ kɔ nipadua mu.
Normal Level a Ɛyɛ Fɛ
Verifies daa nhwehwɛmu pɛpɛɛpɛ wɔ standard physiological ranges ma apɔwmuden reference populations, som sɛ da biara da adwumayɛ benchmark.
Ɔsorosoroni a Ɛkorɔn
Ɔhwehwɛ nhyehyɛe no linearity ne optical adwumayɛ mu wɔ nkwammoaa dodow a ɛkɔ soro mu, hwɛ hu sɛ wosusuw pɛpɛɛpɛ wɔ leukocytosis anaa thrombocytosis tebea horow a emu yɛ den mu.
Nkonimdi ne Calibrator
|
Su a ɛwɔ hɔ |
Calibrator a wɔde yɛ nneɛma |
Kyerɛ kwan |
|
Botae Titiriw |
Ɔyɛ nsakrae wɔ adwinnade akontaabu nneɛma ne detector nkate mu |
Ɔhwɛ susudua a ɛkɔ so pɛpɛɛpɛ ne adwumayɛ mu pɛpɛɛpɛyɛ so |
|
Mpɛn dodow a Wɔde Di Dwuma |
Bere ne bere mu (installation, nsiesie, lot nsakrae, drift) . |
Da biara anaasɛ adwumayɛ sɔhwɛ mmirikatu biara |
|
Botae Dwumadi a Wɔde Ma |
Fixed target values a wɔde ama denam standard reference akwan so |
Wɔakyerɛkyerɛ botaeɛ kwan so a ɛwɔ deviation anohyetoɔ a wɔgye tom |
|
System Adeyɛ |
Ɔyɛ emu mfasoɔ nneɛma ne calibration coefficients foforɔ |
Si so dua sɛ adwinnade ayɛ krado anaasɛ ɛhyɛ adwumayɛ mu mfomso ahorow ho frankaa |
Hematology Analyzers a ɛne ne ho hyia
Wɔayɛ ama sampling channels a wɔabue ne nea wɔato mu wɔ optical scatter, anyinam ahoɔden impedance, ne colorimetric susuw mfiridwuma mu:
- Nsonsonoe analysers a wɔde semiconductor laser apete ne flow cytometry di dwuma
- Impedance cell counting nhyehyɛe ahorow a wɔde hydrodynamic focusing di dwuma
- Cyanide-free hemoglobin colorimetric susudua module ahorow
Nneɛma a Wɔde Ma / Parameters
|
Parameter a wɔde kyerɛ |
Nsɛmfua a wɔatwa no tiaa |
Botae Botae a Wɔde Ma a Wɔtaa De Ma |
Ɔfa |
|
Mogya Nkwammoaa Kɔkɔɔ Dodow |
RBC |
4.50 ± 0.15 |
10¹²/L |
|
Hemoglobin dodow a Ɛwɔ Hɔ |
HGB |
135 ± 3 |
g/L |
|
Hematocrit a ɛwɔ mogya mu |
HCT |
40.0 ± 1.5 |
% |
|
Mean Corpuscular Nnyigyei Nnyigyei |
MCV na ɛwɔ hɔ |
88.0 ± 2.0 |
fL |
|
Mogya Nkwammoaa Fitaa Dodow |
WBC |
7.50 ± 0.30 |
10⁹/L |
|
Neutrophil Ɔha biara mu nkyem 100 |
NEUT% . |
60.0 ± 3.0 |
% |
|
Lymphocyte Ɔha biara mu nkyem 100 |
LYMPH% 100. |
28.0 ± 2.5 |
% |
|
Monocyte Ɔha biara mu nkyem 100 |
MONO% . |
6.0 ± 1.5 |
% |
|
Eosinophil Ɔha biara mu nkyem 100 |
EO% . |
4.0 ± 1.0 |
% |
|
Basophil Ɔha biara mu nkyem 100 |
BASO% 1.1. |
2.0 ± 0.8 |
% |
|
Nkwammoaa mu nkwammoaa dodow |
PLT |
240 ± 15 |
10⁹/L |
Nneɛma a Wɔyɛ no Ho Nsɛm
|
Su |
Mfiridwuma Ho Nsɛm a Wɔakyerɛkyerɛ Mu |
|
Honam fam Tebea |
Woasiesie wo ho-sɛ-de nsuo a ɛsensɛn hɔ bedi dwuma |
|
Matrix Faako a Wɔde Yɛ Adwuma |
Nkwammoaa a wɔde abɔde a nkwa wom a wɔakora so a wɔde ahyɛ mu |
|
Hyɛ Volume no ma |
3.0 mL wɔ aduru biara mu |
|
Traceability Standard a Wɔde Di Dwuma |
Akwan a wɔfa so kyerɛw nsɛm a ɛne ISO 17511 hyia |
|
Nneɛma a Wɔde Gu Nneɛma Mu Nsiesiei |
2 x 3.0 mL / 4 x 3.0 mL / OEM dodow a wɔde ahyɛ mu a wɔayɛ no sɛnea wɔpɛ |
Nneɛma a Wɔkora So & Gyinabea
Ɔhyew a Wɔde Sie:Fa sie tẽẽ wɔ digrii 2 ne digrii 8 ntam . Bɔ ho ban fi awɔw ne hann a ɛbɛda adi tẽẽ ho.
Nkwa Ntraso a Wɔmmue:Nnafua 105 fi da a wɔyɛɛ no bere a wɔde sie bere nyinaa wɔ digrii 2 kosi digrii 8 .
Bue-Vial Gyinabea:Nnafua 7 wɔ aseptic handling a emu yɛ den ase na ntɛm ara san kɔ 2℃to 8℃storage akyi sampling.
Ɔhyew Ho Nneɛma a Wɔde Kɔ:Wɔde nsuo a ɛyɛ nwini-nkɔnsɔnkɔnsɔn a wɔhwɛ so-a wɔhwɛ so wɔ digrii 2 ne digrii 8 ntam na ɛde mena.
Nneɛma a Ɛyɛ Paara
Nhwehwɛmu Ɔkwan a Wɔfa so Hyehyɛ:Nsonsonoe a wɔde ma denam microscopic reference akwan a wɔahyɛ da ayɛ ne master reference instruments a wɔagye atom so.
Homogeneity a Wɔde Di Dwuma:Lot biara kɔ vial-to-vial consistency sɔhwɛ ne coefficient of variation verification ansa na wɔayi no adi.
Nneɛma a Wɔyɛ no Mmara so:Wɔyɛɛ no wɔ ISO 13485 nhyehyɛe a wɔde hwɛ nneɛma pa so ma nnuruyɛ mfiri a wɔde hwehwɛ yare no ase.
Abɔde a Nkwa Wom Ahobammɔ:Nneɛma a wonya fibea a wɔsɔɔ hwɛe sɛ ɛnyɛ-a ɛyɛ adwuma wɔ HBsAg, anti-HCV, ne anti-HIV antibodies ho.
FAQ
Asɛmmisa: Bere bɛn na ɛsɛ sɛ wɔyɛ calibration?
A: Calibration ho hia wɔ mfitiaseɛ adwinnadeɛ a wɔde si hɔ, wɔ optical anaa fluidic nsiesie kɛseɛ akyi, berɛ a wɔresakra reagent lots a ɛkyerɛ nhyehyɛeɛ drift, anaa berɛ a da biara da quality control aba no hwe ase daa wɔ control ranges a wɔakyerɛkyerɛ mu akyi.
Asɛmmisa: So calibrator no ne vial aspiration a wɔabue ne nea wɔato mu nyinaa hyia?
A: Yiw, wɔayɛ nsu a wɔde hyɛ mu no sɛnea ɛbɛyɛ a ɛbɛkɔ so akura viscosity ne nkwammoaa mu kyekyɛ a ɛkɔ so daa wɔ nsaano bue-vial modes ne automated closed-vial sampling nhyehyɛe nyinaa mu.
Asɛmmisa: Ɔkwan bɛn so na wɔde botaeɛ botaeɛ si hɔ ma parameter biara?
A: Wɔde gyinapɛn ahorow a wɔde ama no si hɔ sɛnea ISO 17511 metrological traceability akwankyerɛ kyerɛ, denam nhwɛsode susudua nhyehyɛe a wɔakyerɛ ne standardized master analyzers so.
Asɛmmisa: Ahosiesie bɛn na ɛho hia ansa na wɔafa nhwɛsode?
A: Fa nsa dannan vial no brɛoo mpɛn pii na ama woahwɛ ahu sɛ ɛbɛsensɛn ahina no pɛpɛɛpɛ. Kwati mfiri a ɛwosow ntɛmntɛm na amma foam awo ntoatoaso anaa micro-bubble entrapment a ebetumi asiw optical scatter akenkan kwan.
Asɛmmisa: Ɔkwan bɛn so na wɔhwɛ ma nneɛma a wɔyɛ no mudi mu kura bere a wɔde rekɔ aman horow so no?
A: Nneɛma a wɔde mena no de nsukorade a wɔabɔ ho ban a wɔde awɔw pack ne emu hyew a wɔhwɛ so di dwuma na ama wɔakɔ so ayɛ digrii 2 kosi digrii 8 bere nyinaa wɔ akwantu no nyinaa mu.
Tags a ɛyɛ hyew .: 5-afã hematology analyzer calibrator, China 5-afã mogya mu nhwehwɛmu calibrator manufacturers, suppliers